Kit Library

🎯 Exam Preparation Kit

Electronic Measurement Exam Prep

English 31 leveled MCQs Free

Shared by a Veda learner · Generated with Veda AI

Smart notes

What you'll study, topic by topic

1

Electronic Measurement Exam Prep

Full explanation, worked examples & memory tricks in the app

Solved paper preview

Sample questions with model answers

Every question in the paper gets a full exam-length answer in the app — organised by marks, the way a topper writes it.

5 marks Long answer

Calculate the resonant frequency of the above circuit if the mutual inductance between the coils, M = 20μH.

Show answer outline

Resonant frequency = $f = rac{1}{2\pi\sqrt{LC}}$.

The full exam-length answer is in the app.

5 marks Long answer

Name the transducer shown in the above diagram. What category of transducer does it fall into? Give reasons.

Show answer outline

It is an LVDT; falls under inductive transducers due to its working principle.

The full exam-length answer is in the app.

5 marks Long answer

Calculate the gauge factor of a strain gauge, if the value of resistance is $152 \Omega$, which changes by $5 \Omega$ for $5000 \mu$ strain.

Show answer outline

Gauge factor = $\frac{\Delta R / R}{\epsilon} = \frac{5/152}{5000 \times 10^{-6}}$.

The full exam-length answer is in the app.

4 marks Medium answer

Give reasons for any five of the following: (a) Platinum resistance thermometers are widely used in temperature measurement for industrial applications. (b) Digital storage oscilloscope can keep stored data for months. (c) A multimeter can be used for measuring both dc as well as ac quantities. (d) The electrons tend to converge in the form of a convex lens in the spaces between the anodes. (e) Themistor has a negative resistance effect. (f) Spectrum analyzer is preferred for the measurement of distortion.

Show answer outline

Answers should explain the reasons for each statement.

The full exam-length answer is in the app.

4 marks Medium answer

Differentiate between active and passive pulse generators.

Show answer outline

Active generators require an external power source; passive do not.

The full exam-length answer is in the app.

4 marks Medium answer

Differentiate between LVDT and RVDT.

Show answer outline

LVDT measures linear displacement; RVDT measures angular displacement.

The full exam-length answer is in the app.

4 marks Medium answer

Why is a delay line connected to the vertical amplifier? State the range of the power supply given to the different components of the instrument.

Show answer outline

Delay line compensates for signal timing; power supply range is typically HV and LV.

The full exam-length answer is in the app.

4 marks Medium answer

What are the requirements of the said instrument? State one application of this instrument.

Show answer outline

Requirements include stability and frequency range; application is in RF signal generation.

The full exam-length answer is in the app.

3 marks Medium answer

What does the above diagram represent? Name the components that constitute the heart of this instrument.

Show answer outline

It represents a Cathode Ray Oscilloscope; heart components are the electron gun and deflection plates.

The full exam-length answer is in the app.

3 marks Medium answer

A sinusoidal waveform has peak to peak amplitude of 6cm viewed on the phosphor screen. The vertical sensitivity is set to 5v/cm. calculate the peak voltage and rms value of the signal.

Show answer outline

Peak voltage = 30V; RMS value = 21.21V.

The full exam-length answer is in the app.

3 marks Medium answer

How are the secondary windings connected and why?

Show answer outline

Connected in series opposition to cancel out common mode signals.

The full exam-length answer is in the app.

2 marks Short answer

What is absolute error in measurement?

Show answer outline

The difference between the measured value and the true value.

The full exam-length answer is in the app.

2 marks Short answer

What is the significance of Schmitt trigger in frequency measurement?

Show answer outline

It provides clean switching and noise immunity.

The full exam-length answer is in the app.

2 marks Short answer

What are the phenomenona that govern the operation of a thermocouple?

Show answer outline

Seebeck effect and thermoelectric effect.

The full exam-length answer is in the app.

2 marks Short answer

State one difference between spectrum analyzer and CRO.

Show answer outline

Spectrum analyzer measures frequency components; CRO displays waveforms.

The full exam-length answer is in the app.

2 marks Short answer

What does the above circuit depict? Name the instrument where this circuit is found. What is the other component of this instrument?

Show answer outline

It depicts a transistor-based oscillator; found in signal generators; other component is LC tank circuit.

The full exam-length answer is in the app.

1 marks Short answer

The basic form of bridge for the measurement of resistance.

Show answer outline

Wheatstone bridge

The full exam-length answer is in the app.

1 marks Short answer

The smallest change in a measured value to which an instrument will respond to.

Show answer outline

Resolution

The full exam-length answer is in the app.

1 marks Short answer

The Q meter operates on this principle.

Show answer outline

Resonance

The full exam-length answer is in the app.

1 marks Short answer

Wave meter that can be used for measurement of harmonics.

Show answer outline

Harmonic wave meter

The full exam-length answer is in the app.

1 marks Short answer

It is referred to as the heart of a function generator.

Show answer outline

Oscillator

The full exam-length answer is in the app.

1 marks Short answer

(Piezoelectric/ Thermocouple/ Photovoltaic cell/ LVDT) is a passive transducer.

Show answer outline

Thermocouple

The full exam-length answer is in the app.

1 marks Short answer

Beam of electrons in a cathode ray tube emanates because of (secondary emission/ thermionic emission/ diffusion/ post acceleration).

Show answer outline

thermionic emission

The full exam-length answer is in the app.

1 marks Short answer

The circuit generally used in digital instruments to convert sine waves into rectangular pulses is a (sawtooth generator/ differential amplifier/ sample and hold circuit/ Schmitt trigger).

Show answer outline

Schmitt trigger

The full exam-length answer is in the app.

1 marks Short answer

For the measurement of voltage of the order of mV a (rectifier amplifier/ amplifier rectifier/ diode peak reading/ slide back) type VTVM is used.

Show answer outline

diode peak reading

The full exam-length answer is in the app.

1 marks Short answer

Kelvin's double bridge is used for the measurement of (very high resistance/ very low resistance/ quality factor of a coil/ inductance).

Show answer outline

very low resistance

The full exam-length answer is in the app.

1 marks Short answer

The errors generally caused by human mistakes are ______ errors.

Show answer outline

Human errors

The full exam-length answer is in the app.

1 marks Short answer

A ______ analyzer is an instrument which is used to measure relative amplitudes of a single frequency component in a complex waveform.

Show answer outline

Spectrum

The full exam-length answer is in the app.

1 marks Short answer

Dual trace oscilloscope uses ______ electron gun.

Show answer outline

Dual

The full exam-length answer is in the app.

1 marks Short answer

A thermocouple is a junction of two ______ metals.

Show answer outline

Dissimilar

The full exam-length answer is in the app.

1 marks Short answer

The gauge factor of a strain gauge is always greater than ______.

Show answer outline

1

The full exam-length answer is in the app.

Study it properly — free, in the app

The full Veda Bites deck, complete notes, spaced-repetition flashcards, leveled MCQs, tests and games for this kit — plus Daily Facts and the Arena, every day.